Tuesday, August 20, 2019
Ultrasonic Evaluation of Horizontal Defects
Ultrasonic Evaluation of Horizontal Defects A Novel Method for Ultrasonic Evaluation of Horizontal Defects Using Time-of-Flight Diffraction Abstract Time-of-flight Diffraction method (ToFD) is an amplitude-independent sizing method, which is based on the measurement of time-of-flight of defect tip diffracted waves. Although, ToFD can measure through-wall length of defect accurately, this method is not able to measure horizontal defect size. In this paper, a new time of flight diffraction (ToFD) method for evaluating horizontal planar defects is presented. The finite element method, using ABAQUS software package, is employed to simulate the ultrasonic wave behavior in the test blocks and its interaction with the embedded planar defects. The phased array technology is also used to model the ultrasonic inspection system parameters. FEM simulation of the new ToFD method for different crack sizes shows that, compared to the conventional ToFD method, the accuracy of results is within acceptable range to use the novel technique for measuring the horizontal planar defects. Keywords Ultrasonic wave, diffracted wave, horizontal planar defects, ToFD 1. Introduction Non-destructive testing has been increasingly used to assure the quality and reliability in the oil and gas pipeline industries. The ultrasonic pulse-echo technique uses the pulse flight time to locate the flaw and the echo amplitude to measure the defect size. Since the amplitude of the reflected pulses can be influenced by many parameters, such as beam spread, surface roughness and transparency, using amplitude is not always sufficient for accurate defect sizing (Krautkramer, 1990).The basis of the Time-of-Flight Diffraction (TOFD) technique was invented at the National NDT Centre, Harwell, in the 1970s. Time-of-Flight Diffraction was invented mainly by Silk and his co-workers at the Harwell Laboratory. It was developed over a period of about 10 years starting in the early 1970s, from a laboratory curiosity into a sophisticated full-scale inspection method capable of detecting and sizing defects in components accurately (Silk, 1973, 1974, 1976, 1978)[M1][S2]. The ToFD technique is an amplitude-independent sizing method, based on the measurement of time-of-flight of flaw tips diffracted waves. Golan and Sachese suggested a method to calculate crack size from the time delay between the arrival of a surface longitudinal reference beam and a longitudinal or shear beam diffracted from the tips of crack (Golan, 1980). Mak (Mak, 1983) developed a trigonometric method to calculate location, height and angle of defect by a transducer located in different scan positions. The ToFD technique provides the highest possible accuracy in measuring the depth and through-wall length of defects (Charlesworth et al., 2001), (Baby et al., 2003), (Al-Ataby, 2012). In 1986, finite element simulation of ultrasonic wave propagation and its interaction with defects have been conducted by Ludwig and Lord (Ludwig et al., 1986). The numerical analysis of wave propagation for ToFD in an austenitic stainless steel specimen with consideration of the effects of scattering at grain boundaries was carried out by Lin et al. (Lin et al., 2006), and Connolly (Connolly, 2009). They developed an efficient method for modeling the effects of coarse grains in austenitic materials. In 2007, simulation of the ToFD technique, using finite element method, was carried out by Baskaran et al. They used ANSYS finite element package to model the propagation of ultrasonic waves in a thin cracked two dimensional specimen (Baskaran et al., 2006). In 2010, Honarvar and Khorasani used ABAQUS software package to simulate the propagation of ultrasonic waves and diffraction phenomena. They compared simulated results for drilled-hole diffraction with photo elastic snapshots (Honarv ar and Khorasani et al., 2010). Though, ToFD provides better accuracy in locating and sizing defects than other ultrasonic sizing methods and has a high probability of flaw detection (POD), only through-wall length of the defect can be measured and the defect real size cannot be evaluated (Charlesworth et al., 2001). Therefore, ToFD method cannot be used for measuring and sizing horizontal cracks (horizontal planar defects) (ASME, 2010). In this paper, a new time of flight diffraction (ToFD) method is presented for evaluating and measuring horizontal planar defects. The finite element method, using ABAQUS software package, is employed to simulate the ultrasonic wave behavior in the test blocks and its interaction with the embedded planar defects. The finite element results for different crack sizes are used to study and investigate the presence and generation of different wave modes in the test block and the efficiency and efficacy of the new proposed method. 2. Review of conventional time-of-flight diffraction method (ToFD) The ToFD technique uses tip diffraction to identify the top, bottom, and ends of a discontinuity. Silk chose to use an angled compression wave for the ToFD technique rather than a shear wave, for two reasons. First, the tip diffraction signal is stronger than a shear wave diffraction signal, and second, a lateral wave is produced that can be used to measure the horizontal distance between the transmitter and receiver. The tip diffraction signal is generated at the tip of the discontinuity; effectively a ââ¬Å"pointâ⬠source. According to Huygens (Krautkramer et al., 1990), a point source produces a spherical wave. Figure 1-a shows a typical TOFD transducer set-up on a component with a vertical discontinuity. Figure 1-b shows both the lateral wave and a diffraction beam from the tip of a reflector. There are four sound paths from the transmitter to the receiver. Path ââ¬Å"Aâ⬠is the lateral wave path traveling just below the surface. Path ââ¬Å"Bâ⬠is the tip diffraction path from the top of the discontinuity. Path ââ¬Å"Câ⬠is the tip diffraction path from the bottom of the discontinuity, and path ââ¬Å"Dâ⬠is the back wall echo path. Figure 2 shows a typical un-rectified received signal using ToFD. Note that the phase relationships A and C are in opposite phase to B and D. The important difference to note is between B and C; the top and bottom diffraction signals ar e in opposite phase. This phase difference allows the practitioner to identify those points.[M3] Assuming[S4] that the diffracting tip is centered between the two transducers, the depth of crack tips below the inspection surface can be calculated from (1) [M5][S6](2) and therefore, (3) Where a is the defect through-wall size, d1 is depth of top edge from surface, d2 is depth of bottom edge from surface and 2S is probe separation (see Figure 1-b). C is the longitudinal wave velocity inside the material, t2 and t3 are, respectively, the travel times of waves diffracted from the top and bottom of the crack. 3. Finite element modelingof time-of-flight diffractionmethod In this section, the finite element method (FEM) is used to simulate the ultrasonic wave propagation in the time of flight diffraction technique. The FEM modeling consists of two basic steps; defining mesh configuration and problem discretization, modeling of the transmitting and receiving transducers. ABAQUS finite element software package is employed for analysis and a two-dimensional four-node quadrilateral plane strain element, CPE4R, is used in ABAQUS to discretize a carbon steel test block including vertical crack. See Figure (1-b). The mesh size depends on the frequency of the propagated wave in the sample and the corresponding wavelength. The piezoelectric angle wave transducer, transmitter, is simulated by a transient single frequency pulse wave applying on the surface of the sample. The transient excitation is modeled using a cyclic single frequency pressure/force function as (Mardani et al., 2012), (4) where f is the excitation wave frequency and N is the number of cycles. Using linear delay law for phased array transducers, the compressional excitations can be applied on the sequential elements so that ultrasonic wave propagates at a specific angle, à ¸S. The delay time between adjacent elements, or nodes, is calculated using hyphenââ¬â¢s principle (Olympus NDT, 2007) as, (5) where d is distance between two adjacent elements, à ¸s is steering angle of propagation, C is longitudinal wave speed in the media and Ãât is time delay between two adjacent elements. To investigate the convergence of the results and the appropriate element size for a 2 MHz frequency ultrasonic wave, the signal-to-noise ratio, SNR, is obtained for different element sizes. As it can be seen in Figure 3, at f = 2 MHz, the maximum SNR and SNR convergence occurs for the element sizes smaller than 60 à ¼m. 4. The proposed method As it was mentioned before, using the conventional ToFD method in Eqs. (1) to (3), the difference between time-of-flight diffractions of upper and lower crack tips gives the defect through-wall size and the actual defect size cannot be measured. This means that the conventional ToFD technique leads to large errors for oblique defects and cannot also be used for horizontal defects. In the proposed method, a novel configuration and the corresponding formula are used so that the ToFD method can be employed to evaluate horizontal planar defects. Figure 4 shows the proposed ToFD configuration on the specimen with a horizontal planar discontinuity. As it can be seen, in this configuration, two transducers including a transmitter/receiver, No. 1 and a receiver, No. 2, are located at the both sides of defect. The ultrasonic wave propagation, in this configuration, is simulated using ABAQUS to study the behavior of ultrasonic wave modes in the test block and their interaction with the defect. In Figure 5, the different incident ultrasonic wave modes are shown. The transmitting transducer, T1, emits a short pulse of ultrasonic wave, longitudinal wave, into the component and energy spreads out as it propagates into the specimen. If the crack face is smooth, there will be a mirror-like reflection of the wave incident on the face. See Figure 6. For any horizontal planar discontinuity, whether smooth or rough-faced, diffraction from the edges of the defect causes some fraction of the incident energy travel towards the receiving transducers R1and R2 in longitudinal and shear modes with different wave velocity. As it can be seen in Figures 6 and 7, the mode conversion behavior due to the interaction of ultrasonic wave with the defect leads to the presence of longitudinal and shear waves from each tips of the defect. Moreover, three different wave modes, including longitudinal lateral, shear lateral and Rayleigh waves travel from the transmitting transducer, T1, to the receiving transducer, R2. See Figure 5. If the crack is large enough, the signals from the two end of defect will be sufficiently separated in time to be recognized as coming from separate sources. Therefore, using this configuration and the related ultrasonic wave propagation simulation, the time difference between the received longitudinal diffracted waves from the left and right defect tips to each receiver, R1 and R2, can be employed to measure the horizontal defect size. It should be noted that the new method can also be used for evaluating the vertical defects. To calculate the horizontal defect size using Pythagorasââ¬â¢ theorem gives, [M7] (6[S8]) and (7) where t1 is the arrival time of the signal diffracted from the left tip of the defect by receiver 1, R1, and t2 is the arrival time of the signal diffracted from the right tip of the defect by receiver 2, R2. CL is the longitudinal wave velocity and 2S is the separation between the transducers. 5. Results and Discussions To investigate the efficiency and efficacy of the proposed method, using finite element modeling, the novel method is carried out on eight carbon steel blocks with different size embedded horizontal cracks. The test blocks have 100 mm lengths and 20à ¯Ãâà 20 mm2 cross sections and are modeled with ABAQUS finite element software package using CPE4R plane strain elements. The acoustic and elastic properties of carbon steel are given in Table 1[M9][S10]. Each block contains a horizontal planar defect. The defects have 2, 4, 6, 8, 10, 12, 14 and 16 mm length and 12 mm depth, see Figure 4. The transmitter is modeled as an 8-element 2 MHz phased array transducer. Each element of the phased array transducer has 0.5 mm length and the gap space between two adjacent elements is 0.1 mm. The first receiving transducer is located on the position of the transmitter and the second is located at 35 mm distance from the transmitter on the inspection surface, 2S = 35 mm. The ABAQUS finite elemen t software package is used to simulate the new ultrasonic ToFD method. The received signals at the first and the second receivers are shown in Figures 8 and 9. In Figure 8, the first echo is related to the transient pulse waves, Eq. (4), generated by the eight elements of the phased array transducer using a specific delay times, Eq. (5), which receives at the first receiver, initial pulse. In this signal, the second echo is related to wave diffraction from the left tip of the defect which is detected by the first receiver, R1. The back-wall reflection from back surface of the block is shown as the third echo in this figure. Figure 9 shows the signal received by the second transducer, R2. In this signal, the first echo is due to the longitudinal mode of the lateral wave which travels from transmitter to the receiver 2, R2, and the second echo is diffracted wave from the right tip of the horizontal defect. Figures 5, 6 and 7 show the corresponding waves propagated in the test block. U sing the signals detected by the receiving transducers, the corresponding times due to diffracted echoes from the defect tips (left and right) are determined, and then the horizontal defect size is measured using Eqs. (6) and (7). The new method is carried out on eight carbon steel blocks with different size embedded horizontal cracks. The measured crack size resulting from FEM simulation of each block is shown in Table 2. Comparing the simulated and the measured crack size results shows that the maximum error is %19.7 which occurs at 2 mm crack size. As it can be seen in Table 2, the measured crack size error is minimized within the crack size range of 8 14 mm and is slightly increased for larger defects. This agrees with the conventional ToFD results which show higher measurement errors at smaller crack sizes (Charlesworth et al., 2001). Considering the simulated results of different crack size shown in Table 2, show that accuracy of the proposed method for horizontal cracks, comparing to the conventional method for vertical cracks, is within acceptable range. 6. Conclusions In this paper, a new time of flight diffraction (ToFD) method to evaluate horizontal planar defects was presented. The finite element method was employed to simulate the ultrasonic wave behavior in the test blocks and its interaction with the embedded planar defects, such as crack. The phased array technology was also used to model the ultrasonic inspection system parameters. Simulation of the new ToFD method for different crack sizes, using ABAQUS finite element package, showed that, comparing to the conventional ToFD method, the result accuracies are within acceptable range to use the novel technique for measuring the horizontal planar defects. [M11]Using[S12] the new method for eight carbon steel blocks with different size horizontal cracks (2ââ¬â16 mm) showed that the maximum error occurs at 2 mm crack length. Also, it was observed that the measured crack size error is minimized within the range of 8 14 mm and is slightly increased for larger defects. References Al-Ataby, A. A., Automatic detection, Sizing and Characterization of Weld Defects Using Ultrasonic Time-of-Flight Diffraction, PhD Dissertation, Liverpool University, p.95-96, 2012. American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel code, Section V, Non Destructive Examination. Appendix N time of flight diffraction (TOFD) Interpretation, Article 4, 2010. Baby, S., Balasubramanian, T. , Pardikar, R.J., Palaniappan, M. , and Subbaratnam, R. , Time-of-Flight Diffraction (TOFD) Technique for Accurate Sizing of Surface-breaking Cracks, Insight, June, Vol. 45, No. 6, p. 426-430, 2003. Baskaran, G., Balasubramaniam, K., and Lakshmana Rao, C., Shear Wave Time-of-flight Diffraction (S-ToFD) Technique, NDTE International, Vol. 39, p.458-467, 2006. Charlesworth, J. P., and Temple, J. A. G., Engineering Applications of Ultrasonic Time of Flight Diffraction, England, RSP Press , p.20-28,2001. Connolly, G.D., Modeling of the Propagation of Ultrasound through Austenitic Steel Welds, Ph.D.Dissertation, UK Research Centre in NDE (RCNDE) Department of Mechanical Engineering Imperial College London, 2009. Golan, S., Sizing of Cracks with Scattered Ultrasonic Waves, Proceeding of First International Symposium Ultrasonic Characterization, p. 29-36, 1980. Hellier, C. J., Handbook of Nondestructive Evaluation, McGraw Hill, 2003. Honarvar, F., and Khorasani, S., Simulation of Time of Flight Diffraction (ToFD) Technique by Finite Element Method, Online Workshop in www.ndt.net, September, 2010. Krautkramer, J., and krautkramer, H., Ultrasonic Testing of Materials, Berlin, Springer-Verlag, 1990. Lin, S., Futomi, H., and Ogata, T., Analysis of Wave Propagation for the ToFD Method by Finite Eement Method: Optimization of Test Configuration and Proposal of a New ToFD Method, Nondestructive Evaluation, Vol. 25, 2006. Ludwig and, R., and, Lord, W., Developments in the Finite Element Modeling of Ultrasonic NDT Phenomena, Review of Progress in Quantitative Nondestructive Evaluation, 5A, American Institute of Physics, p.73-81, 1986. Mak, D.K., Ultrasonic Method for Measuring Crack Location, Crack Height and Crack Angle, Ultrasonics, p.259-270, 1983. Mardani, M., Sodagar, S., and Rashed, G. R., Modeling of Ultrasonic Phased Array Method Using Finite Element Method, ISME2012, Shiraz, Iran. Olympus NDT, Advances in Phased Array Ultrasonic Technology Applications, Waltham, 2007. Silk, M.G., Defect detection and sizing in metal using ultrasound, Int. Metall, V.27, pp28-50, 1973. Silk, M.G., Accurate Technique for Defect Sizing in Pressurized Components, London, Institution of Mechanical Engineers, V.3, pp155-162, 1974. Silk, M.G., Defect Sizing Using Ultrasonic Diffraction, British Journal of Nondestructive Test, V.21, p.12-15, 1976. Silk, M.G., The Use of Diffraction-based Ttime-of-flight Measurement to Locate and Size Defects, British journal of Nondestructive Test, Vol. 26, p.208-213, 1978. [M1]please shorten this and delete repeated and unnecessary information. [S2]Done [M3]How do you see these in Figure 2? [S4]It can be explained by: The maximum amplitude at first (A) and third (C) echoes at tL and t2 are dip (negative) and the maximum amplitude at second (B) and fifth (D) are peak (positive). [M5]Show ââ¬Å"Sâ⬠in figure 1-b. [S6]Done [M7]Show all parameters in the figures. [S8]Done. [M9]Give all units in this table. [S10]Done. [M11]This is more like an abstract than conclusions. It adds nothing to the paper. [S12]Done.
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.